Environment Sensors

Temperature & Humidty

DPX-T1
Single temperature sensor, 10 ft. (3m) cable length, RJ-12 connector.

DPX-T1H1
Single combo temperature and humidity sensor, 10ft (3m) cable, RJ-12 connector
DPX3-T1H1

Single combo temperature and humidity sensor, field replaceable sensor modules, 10ft (3m) cable, RJ-45 connector (Not supported by DPX and PX models.)

DPX-T2H2
Dual combo temperature and humidity sensors, 10ft (3m) cable from RJ-12 connector to combined temperature/humidity sensor, additional 10ft (3m) cable to second combined temperature/humidity sensor (total length 20ft/6m).

DPX3-T2H2-KIT
Two single combo temperature and humidity sensors, field replaceable modules, 10ft (3m) cable,RJ-12 connector

DPX-T3H1
Three temperature sensors, middle sensor supporting humidity (four sensors total in three housings), 13ft (4m) cable from RJ-12 connector to first sensor, 3ft (1m) between first and second and second and third sensor housings.

DPX2-T3H1
Three temperature sensors, middle sensor supporting humidity (four sensors total in three housings),field replaceable sensor modules, 10ft (3m) cable from RJ-12 connector to first sensor, 3ft (1m) between first and second and second and third sensor housings (Not supported by DPX and PX models.)

Air Flow / Pressure

DPX-AF1
Single airflow sensor with 10ft (3m) cable and RJ-12 connector. It is designed to monitor airflow such as cooling air blowing through a perforated tile.

DPX-T1DP1
Differential air pressure sensor with 10ft (3m) cable and RJ-12 connector. It is designed to monitor two air pressures such as the air pressure on either side of a thermal curtain separating a cold aisle from a hot aisle or above and below a raised floor or overhead plenum.

External Input Contacts

DPX-CC2-TR
Dual contact closure sensor for use with third-party Normally Closed (NC) or Normally Open (NO) switches such as door open or closed, door locked or unlocked, smoke present or absent, etc.

DX-PD2C5
Two active dry contacts powered by 12V to support door locks. Five digital Normally Closed (NC) or Normally Open (NO) contact closures which require customer-provided NC or NO switches, e.g. door open/close, smoke present/absent, etc. Each of the five ports (channels) can be independently set to NC or NO, factory default is NC, RJ-45 connector (Not supported by DPX, PX or PX2 models).

Wet Floor

DPX-WSF-KIT
Floor water/leak sensor and a contact closure sensor for detecting water or water and glycol leaks. Reliably warns of water leaks at critical points below a raised floor.

DPX-WSC-35-KIT
3.5m rope water/leak sensor and a contact closure sensor for detecting water or water and glycol leaks. Detect leaks easily anywhere along the length of this flexible cable. Wrap around a rack with in-row cooling.

DPX-WSC-70-KIT
7m rope water/leak sensor and a contact closure sensor for detecting water or water and glycol leaks. Detect leaks easily anywhere along the length of this flexible cable. The long length allows you to encircle a data center CRAC unit.

Expansion Hubs

DPX-ENVHUB2
Two-port (1×2) hub to expand RJ-12 sensor ports, comes with mounting bracket and RJ-12-to-RJ-12 cable to connect to, and receive power from, PX and EMX products.

DPX3-ENVHUB4
Four-port (1×4) hub to expand RJ-45 sensor ports, comes with mounting bracket.

Vibration / Proximity

DX-VBR
Vibration sensor which detects acceleration along three axes (x, y, z). RJ-45 connector.

DX-PIR
Digital proximity sensor which detects motion around a cabinet, RJ-45 connector (Not supported by DPX, PX or PX2 models).